1 | NET AUDIO_BIT_CLK LOC="AF18"; # Bank 4, Vcco=3.3V, No DCI |
---|
2 | NET AUDIO_SDATA_IN LOC="AE18"; # Bank 4, Vcco=3.3V, No DCI |
---|
3 | NET AUDIO_SDATA_OUT LOC="AG16"; # Bank 4, Vcco=3.3V, No DCI |
---|
4 | NET AUDIO_SYNC LOC="AF19"; # Bank 4, Vcco=3.3V, No DCI |
---|
5 | NET BUS_ERROR_1 LOC="F6"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
6 | NET BUS_ERROR_2 LOC="T10"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
7 | NET CFG_ADDR_OUT0 LOC="AE12"; # Bank 2, Vcco=3.3V |
---|
8 | NET CFG_ADDR_OUT1 LOC="AE13"; # Bank 2, Vcco=3.3V |
---|
9 | NET CLK_27MHZ_FPGA LOC="AG18"; # Bank 4, Vcco=3.3V, No DCI |
---|
10 | NET CLK_33MHZ_FPGA LOC="AH17"; # Bank 4, Vcco=3.3V, No DCI |
---|
11 | NET CLK_FPGA_N LOC="K19"; # Bank 3, Vcco=2.5V, No DCI |
---|
12 | NET CLK_FPGA_P LOC="L19"; # Bank 3, Vcco=2.5V, No DCI |
---|
13 | NET CLKBUF_Q0_N LOC="H3"; # Bank 116, MGTREFCLKN_116, GTP_DUAL_X0Y4 |
---|
14 | NET CLKBUF_Q0_P LOC="H4"; # Bank 116, MGTREFCLKP_116, GTP_DUAL_X0Y4 |
---|
15 | NET CLKBUF_Q1_N LOC="J19"; # Bank 3, Vcco=2.5V, No DCI |
---|
16 | NET CLKBUF_Q1_P LOC="K18"; # Bank 3, Vcco=2.5V, No DCI |
---|
17 | NET CPLD_IO_1 LOC="W10"; # Bank 18, Vcco=3.3V, No DCI |
---|
18 | NET CPU_TCK LOC="E6"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
19 | NET CPU_TDO LOC="E7"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
20 | NET CPU_TMS LOC="U10"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
21 | NET CPU_TRST LOC="V10"; # Bank 18, Vcco=3.3V, No DCI |
---|
22 | NET DDR2_A0 LOC="L30"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
23 | NET DDR2_A1 LOC="M30"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
24 | NET DDR2_A2 LOC="N29"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
25 | NET DDR2_A3 LOC="P29"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
26 | NET DDR2_A4 LOC="K31"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
27 | NET DDR2_A5 LOC="L31"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
28 | NET DDR2_A6 LOC="P31"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
29 | NET DDR2_A7 LOC="P30"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
30 | NET DDR2_A8 LOC="M31"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
31 | NET DDR2_A9 LOC="R28"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
32 | NET DDR2_A10 LOC="J31"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
33 | NET DDR2_A11 LOC="R29"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
34 | NET DDR2_A12 LOC="T31"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
35 | NET DDR2_A13 LOC="H29"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
36 | NET DDR2_BA0 LOC="G31"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
37 | NET DDR2_BA1 LOC="J30"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
38 | NET DDR2_BA2 LOC="R31"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
39 | NET DDR2_CAS_B LOC="E31"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
40 | NET DDR2_CKE0 LOC="T28"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
41 | NET DDR2_CKE1 LOC="U30"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
42 | NET DDR2_CLK0_N LOC="AJ29"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
43 | NET DDR2_CLK0_P LOC="AK29"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
44 | NET DDR2_CLK1_N LOC="F28"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
45 | NET DDR2_CLK1_P LOC="E28"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
46 | NET DDR2_CS0_B LOC="L29"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
47 | NET DDR2_CS1_B LOC="J29"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
48 | NET DDR2_D0 LOC="AF30"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
49 | NET DDR2_D1 LOC="AK31"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
50 | NET DDR2_D2 LOC="AF31"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
51 | NET DDR2_D3 LOC="AD30"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
52 | NET DDR2_D4 LOC="AJ30"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
53 | NET DDR2_D5 LOC="AF29"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
54 | NET DDR2_D6 LOC="AD29"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
55 | NET DDR2_D7 LOC="AE29"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
56 | NET DDR2_D8 LOC="AH27"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
57 | NET DDR2_D9 LOC="AF28"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
58 | NET DDR2_D10 LOC="AH28"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
59 | NET DDR2_D11 LOC="AA28"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
60 | NET DDR2_D12 LOC="AG25"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
61 | NET DDR2_D13 LOC="AJ26"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
62 | NET DDR2_D14 LOC="AG28"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
63 | NET DDR2_D15 LOC="AB28"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
64 | NET DDR2_D16 LOC="AC28"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
65 | NET DDR2_D17 LOC="AB25"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
66 | NET DDR2_D18 LOC="AC27"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
67 | NET DDR2_D19 LOC="AA26"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
68 | NET DDR2_D20 LOC="AB26"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
69 | NET DDR2_D21 LOC="AA24"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
70 | NET DDR2_D22 LOC="AB27"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
71 | NET DDR2_D23 LOC="AA25"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
72 | NET DDR2_D24 LOC="AC29"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
73 | NET DDR2_D25 LOC="AB30"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
74 | NET DDR2_D26 LOC="W31"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
75 | NET DDR2_D27 LOC="V30"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
76 | NET DDR2_D28 LOC="AC30"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
77 | NET DDR2_D29 LOC="W29"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
78 | NET DDR2_D30 LOC="V27"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
79 | NET DDR2_D31 LOC="W27"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
80 | NET DDR2_D32 LOC="V29"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
81 | NET DDR2_D33 LOC="Y27"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
82 | NET DDR2_D34 LOC="Y26"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
83 | NET DDR2_D35 LOC="W24"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
84 | NET DDR2_D36 LOC="V28"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
85 | NET DDR2_D37 LOC="W25"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
86 | NET DDR2_D38 LOC="W26"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
87 | NET DDR2_D39 LOC="V24"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
88 | NET DDR2_D40 LOC="R24"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
89 | NET DDR2_D41 LOC="P25"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
90 | NET DDR2_D42 LOC="N24"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
91 | NET DDR2_D43 LOC="P26"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
92 | NET DDR2_D44 LOC="T24"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
93 | NET DDR2_D45 LOC="N25"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
94 | NET DDR2_D46 LOC="P27"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
95 | NET DDR2_D47 LOC="N28"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
96 | NET DDR2_D48 LOC="M28"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
97 | NET DDR2_D49 LOC="L28"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
98 | NET DDR2_D50 LOC="F25"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
99 | NET DDR2_D51 LOC="H25"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
100 | NET DDR2_D52 LOC="K27"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
101 | NET DDR2_D53 LOC="K28"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
102 | NET DDR2_D54 LOC="H24"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
103 | NET DDR2_D55 LOC="G26"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
104 | NET DDR2_D56 LOC="G25"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
105 | NET DDR2_D57 LOC="M26"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
106 | NET DDR2_D58 LOC="J24"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
107 | NET DDR2_D59 LOC="L26"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
108 | NET DDR2_D60 LOC="J27"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
109 | NET DDR2_D61 LOC="M25"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
110 | NET DDR2_D62 LOC="L25"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
111 | NET DDR2_D63 LOC="L24"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
112 | NET DDR2_DM0 LOC="AJ31"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
113 | NET DDR2_DM1 LOC="AE28"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
114 | NET DDR2_DM2 LOC="Y24"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
115 | NET DDR2_DM3 LOC="Y31"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
116 | NET DDR2_DM4 LOC="V25"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
117 | NET DDR2_DM5 LOC="P24"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
118 | NET DDR2_DM6 LOC="F26"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
119 | NET DDR2_DM7 LOC="J25"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
120 | NET DDR2_DQS0_N LOC="AA30"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
121 | NET DDR2_DQS0_P LOC="AA29"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
122 | NET DDR2_DQS1_N LOC="AK27"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
123 | NET DDR2_DQS1_P LOC="AK28"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
124 | NET DDR2_DQS2_N LOC="AJ27"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
125 | NET DDR2_DQS2_P LOC="AK26"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
126 | NET DDR2_DQS3_N LOC="AA31"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
127 | NET DDR2_DQS3_P LOC="AB31"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
128 | NET DDR2_DQS4_N LOC="Y29"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
129 | NET DDR2_DQS4_P LOC="Y28"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
130 | NET DDR2_DQS5_N LOC="E27"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
131 | NET DDR2_DQS5_P LOC="E26"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
132 | NET DDR2_DQS6_N LOC="G28"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
133 | NET DDR2_DQS6_P LOC="H28"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
134 | NET DDR2_DQS7_N LOC="H27"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
135 | NET DDR2_DQS7_P LOC="G27"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
136 | NET DDR2_ODT0 LOC="F31"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
137 | NET DDR2_ODT1 LOC="F30"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
138 | NET DDR2_RAS_B LOC="H30"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
139 | NET DDR2_SCL LOC="E29"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
140 | NET DDR2_SDA LOC="F29"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
141 | NET DDR2_WE_B LOC="K29"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
142 | NET DVI_D0 LOC="AB8"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
143 | NET DVI_D1 LOC="AC8"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
144 | NET DVI_D2 LOC="AN12"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
145 | NET DVI_D3 LOC="AP12"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
146 | NET DVI_D4 LOC="AA9"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
147 | NET DVI_D5 LOC="AA8"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
148 | NET DVI_D6 LOC="AM13"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
149 | NET DVI_D7 LOC="AN13"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
150 | NET DVI_D8 LOC="AA10"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
151 | NET DVI_D9 LOC="AB10"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
152 | NET DVI_D10 LOC="AP14"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
153 | NET DVI_D11 LOC="AN14"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
154 | NET DVI_DE LOC="AE8"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
155 | NET DVI_GPIO1 LOC="N30"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
156 | NET DVI_H LOC="AM12"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
157 | NET DVI_RESET_B LOC="AK6"; # Bank 18, Vcco=3.3V, No DCI |
---|
158 | NET DVI_V LOC="AM11"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
159 | NET DVI_XCLK_N LOC="AL10"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
160 | NET DVI_XCLK_P LOC="AL11"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
161 | NET FAN_ALERT_B LOC="T30"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
162 | NET FLASH_ADV_B LOC="F13"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
163 | NET FLASH_AUDIO_RESET_B LOC="AG17"; # Bank 4, Vcco=3.3V, No DCI |
---|
164 | NET FLASH_CE_B LOC="AE14"; # Bank 2, Vcco=3.3V |
---|
165 | NET FLASH_CLK LOC="N9"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
166 | NET FLASH_OE_B LOC="AF14"; # Bank 2, Vcco=3.3V |
---|
167 | NET FLASH_WAIT LOC="G13"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
168 | NET FPGA_AVDD LOC="T18"; # Bank 0, Vcco=3.3V |
---|
169 | NET FPGA_CCLK-R LOC="N15"; # Bank 0, Vcco=3.3V |
---|
170 | NET FPGA_CPU_RESET_B LOC="E9"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
171 | NET FPGA_CS_B LOC="N22"; # Bank 0, Vcco=3.3V |
---|
172 | NET FPGA_CS0_B LOC="AF21"; # Bank 2, Vcco=3.3V |
---|
173 | NET FPGA_DIFF_CLK_OUT_N LOC="J21"; # Bank 3, Vcco=2.5V, No DCI |
---|
174 | NET FPGA_DIFF_CLK_OUT_P LOC="J20"; # Bank 3, Vcco=2.5V, No DCI |
---|
175 | NET FPGA_DIN LOC="P15"; # Bank 0, Vcco=3.3V |
---|
176 | NET FPGA_DONE LOC="M15"; # Bank 0, Vcco=3.3V |
---|
177 | NET FPGA_DOUT_BUSY LOC="AD15"; # Bank 0, Vcco=3.3V |
---|
178 | NET FPGA_DX_N LOC="W17"; # Bank 0, Vcco=3.3V |
---|
179 | NET FPGA_DX_P LOC="W18"; # Bank 0, Vcco=3.3V |
---|
180 | NET FPGA_EXP_TCK LOC="AB15"; # Bank 0, Vcco=3.3V |
---|
181 | NET FPGA_EXP_TMS LOC="AC14"; # Bank 0, Vcco=3.3V |
---|
182 | NET FPGA_HSWAPEN LOC="M23"; # Bank 0, Vcco=3.3V |
---|
183 | NET FPGA_INIT_B LOC="N14"; # Bank 0, Vcco=3.3V |
---|
184 | NET FPGA_M0 LOC="AD21"; # Bank 0, Vcco=3.3V |
---|
185 | NET FPGA_M1 LOC="AC22"; # Bank 0, Vcco=3.3V |
---|
186 | NET FPGA_M2 LOC="AD22"; # Bank 0, Vcco=3.3V |
---|
187 | NET FPGA_PROG_B LOC="M22"; # Bank 0, Vcco=3.3V |
---|
188 | NET FPGA_RDWR_B LOC="N23"; # Bank 0, Vcco=3.3V |
---|
189 | NET FPGA_ROTARY_INCA LOC="AH30"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
190 | NET FPGA_ROTARY_INCB LOC="AG30"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
191 | NET FPGA_ROTARY_PUSH LOC="AH29"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
192 | NET FPGA_SERIAL1_RX LOC="AG15"; # Bank 4, Vcco=3.3V, No DCI |
---|
193 | NET FPGA_SERIAL1_TX LOC="AG20"; # Bank 4, Vcco=3.3V, No DCI |
---|
194 | NET FPGA_SERIAL2_RX LOC="G10"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
195 | NET FPGA_SERIAL2_TX LOC="F10"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
196 | NET FPGA_TDI LOC="AC15"; # Bank 0, Vcco=3.3V |
---|
197 | NET FPGA_TDO LOC="AD14"; # Bank 0, Vcco=3.3V |
---|
198 | NET FPGA_V_N LOC="V17"; # Bank 0, Vcco=3.3V (SYSMON External Input: VN) J9-10 |
---|
199 | NET FPGA_V_P LOC="U18"; # Bank 0, Vcco=3.3V (SYSMON External Input: VP) J9-9 |
---|
200 | NET FPGA_VBATT LOC="L23"; # Bank 0, Vcco=3.3V |
---|
201 | NET FPGA_VREFP LOC="V18"; # Bank 0, Vcco=3.3V |
---|
202 | NET FPGA_VRN_B11 LOC="N33"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 |
---|
203 | NET FPGA_VRN_B13 LOC="AG33"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 |
---|
204 | NET FPGA_VRN_B17 LOC="AD31"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
205 | NET FPGA_VRN_B19 LOC="N27"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
206 | NET FPGA_VRN_B20 LOC="L10"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
207 | NET FPGA_VRN_B21 LOC="AJ25"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
208 | NET FPGA_VRN_B22 LOC="AF8"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
209 | NET FPGA_VRP_B11 LOC="M33"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 |
---|
210 | NET FPGA_VRP_B13 LOC="AH33"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 |
---|
211 | NET FPGA_VRP_B17 LOC="AE31"; # Bank 17, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
212 | NET FPGA_VRP_B19 LOC="M27"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
213 | NET FPGA_VRP_B20 LOC="L11"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
214 | NET FPGA_VRP_B21 LOC="AH25"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
215 | NET FPGA_VRP_B22 LOC="AE9"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
216 | NET GPIO_DIP_SW1 LOC="U25"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
217 | NET GPIO_DIP_SW2 LOC="AG27"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
218 | NET GPIO_DIP_SW3 LOC="AF25"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
219 | NET GPIO_DIP_SW4 LOC="AF26"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
220 | NET GPIO_DIP_SW5 LOC="AE27"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
221 | NET GPIO_DIP_SW6 LOC="AE26"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
222 | NET GPIO_DIP_SW7 LOC="AC25"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
223 | NET GPIO_DIP_SW8 LOC="AC24"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
224 | NET GPIO_LED_0 LOC="H18"; # Bank 3, Vcco=2.5V, No DCI |
---|
225 | NET GPIO_LED_1 LOC="L18"; # Bank 3, Vcco=2.5V, No DCI |
---|
226 | NET GPIO_LED_2 LOC="G15"; # Bank 3, Vcco=2.5V, No DCI |
---|
227 | NET GPIO_LED_3 LOC="AD26"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
228 | NET GPIO_LED_4 LOC="G16"; # Bank 3, Vcco=2.5V, No DCI |
---|
229 | NET GPIO_LED_5 LOC="AD25"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
230 | NET GPIO_LED_6 LOC="AD24"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
231 | NET GPIO_LED_7 LOC="AE24"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
232 | NET GPIO_LED_C LOC="E8"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
233 | NET GPIO_LED_E LOC="AG23"; # Bank 2, Vcco=3.3V |
---|
234 | NET GPIO_LED_N LOC="AF13"; # Bank 2, Vcco=3.3V |
---|
235 | NET GPIO_LED_S LOC="AG12"; # Bank 2, Vcco=3.3V |
---|
236 | NET GPIO_LED_W LOC="AF23"; # Bank 2, Vcco=3.3V |
---|
237 | NET GPIO_SW_C LOC="AJ6"; # Bank 18, Vcco=3.3V, No DCI |
---|
238 | NET GPIO_SW_E LOC="AK7"; # Bank 18, Vcco=3.3V, No DCI |
---|
239 | NET GPIO_SW_N LOC="U8"; # Bank 18, Vcco=3.3V, No DCI |
---|
240 | NET GPIO_SW_S LOC="V8"; # Bank 18, Vcco=3.3V, No DCI |
---|
241 | NET GPIO_SW_W LOC="AJ7"; # Bank 18, Vcco=3.3V, No DCI |
---|
242 | NET HDR1_2 LOC="H33"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 |
---|
243 | NET HDR1_4 LOC="F34"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 |
---|
244 | NET HDR1_6 LOC="H34"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 |
---|
245 | NET HDR1_8 LOC="G33"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 |
---|
246 | NET HDR1_10 LOC="G32"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 |
---|
247 | NET HDR1_12 LOC="H32"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 |
---|
248 | NET HDR1_14 LOC="J32"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 |
---|
249 | NET HDR1_16 LOC="J34"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 |
---|
250 | NET HDR1_18 LOC ="L33"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 |
---|
251 | NET HDR1_20 LOC="M32"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 |
---|
252 | NET HDR1_22 LOC="P34"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 |
---|
253 | NET HDR1_24 LOC="N34"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 |
---|
254 | NET HDR1_26 LOC="AA34"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[5]) J6-26 |
---|
255 | NET HDR1_28 LOC="AD32"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 |
---|
256 | NET HDR1_30 LOC="Y34"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[5]) J6-30 |
---|
257 | NET HDR1_32 LOC="Y32"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 |
---|
258 | NET HDR1_34 LOC="W32"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 |
---|
259 | NET HDR1_36 LOC="AH34"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 |
---|
260 | NET HDR1_38 LOC="AE32"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 |
---|
261 | NET HDR1_40 LOC="AG32"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 |
---|
262 | NET HDR1_42 LOC="AH32"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 |
---|
263 | NET HDR1_44 LOC="AK34"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 |
---|
264 | NET HDR1_46 LOC="AK33"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 |
---|
265 | NET HDR1_48 LOC="AJ32"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 |
---|
266 | NET HDR1_50 LOC="AK32"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 |
---|
267 | NET HDR1_52 LOC="AL34"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 |
---|
268 | NET HDR1_54 LOC="AL33"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 |
---|
269 | NET HDR1_56 LOC="AM33"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 |
---|
270 | NET HDR1_58 LOC="AJ34"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 |
---|
271 | NET HDR1_60 LOC="AM32"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 |
---|
272 | NET HDR1_62 LOC="AN34"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 |
---|
273 | NET HDR1_64 LOC="AN33"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 |
---|
274 | NET HDR2_2_SM_8_N LOC="K34"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[15]) J4-2 |
---|
275 | NET HDR2_4_SM_8_P LOC="L34"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[15]) J4-4 |
---|
276 | NET HDR2_6_SM_7_N LOC="K32"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[14]) J4-6 |
---|
277 | NET HDR2_8_SM_7_P LOC="K33"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[14]) J4-8 |
---|
278 | NET HDR2_10_DIFF_0_N LOC="N32"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[13]) J4-10 |
---|
279 | NET HDR2_12_DIFF_0_P LOC="P32"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[13]) J4-12 |
---|
280 | NET HDR2_14_DIFF_1_N LOC="R34"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[12]) J4-14 |
---|
281 | NET HDR2_16_DIFF_1_P LOC="T33"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[12]) J4-16 |
---|
282 | NET HDR2_18_DIFF_2_N LOC="R32"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[11]) J4-18 |
---|
283 | NET HDR2_20_DIFF_2_P LOC="R33"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[11]) J4-20 |
---|
284 | NET HDR2_22_SM_10_N LOC="T34"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[10]) J4-22 |
---|
285 | NET HDR2_24_SM_10_P LOC="U33"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[10]) J4-24 |
---|
286 | NET HDR2_26_SM_11_N LOC="U31"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[9]) J4-26 |
---|
287 | NET HDR2_28_SM_11_P LOC="U32"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[9]) J4-28 |
---|
288 | NET HDR2_30_DIFF_3_N LOC="V33"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[8]) J4-30 |
---|
289 | NET HDR2_32_DIFF_3_P LOC="V32"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[8]) J4-32 |
---|
290 | NET HDR2_34_SM_15_N LOC="V34"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[7]) J4-34 |
---|
291 | NET HDR2_36_SM_15_P LOC="W34"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[7]) J4-36 |
---|
292 | NET HDR2_38_SM_6_N LOC="AA33"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[6]) J4-38 |
---|
293 | NET HDR2_40_SM_6_P LOC="Y33"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[6]) J4-40 |
---|
294 | NET HDR2_42_SM_14_N LOC="AE34"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[0]) J4-42 |
---|
295 | NET HDR2_44_SM_14_P LOC="AF34"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[0]) J4-44 |
---|
296 | NET HDR2_46_SM_12_N LOC="AE33"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[1]) J4-46 |
---|
297 | NET HDR2_48_SM_12_P LOC="AF33"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[1]) J4-48 |
---|
298 | NET HDR2_50_SM_5_N LOC="AD34"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[4]) J4-50 |
---|
299 | NET HDR2_52_SM_5_P LOC="AC34"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[4]) J4-52 |
---|
300 | NET HDR2_54_SM_13_N LOC="AB32"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[3]) J4-54 |
---|
301 | NET HDR2_56_SM_13_P LOC="AC32"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[3]) J4-56 |
---|
302 | NET HDR2_58_SM_4_N LOC="AB33"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXN[2]) J4-58 |
---|
303 | NET HDR2_60_SM_4_P LOC="AC33"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 (SYSMON External Input: VAUXP[2]) J4-60 |
---|
304 | NET HDR2_62_SM_9_N LOC="AP32"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 |
---|
305 | NET HDR2_64_SM_9_P LOC="AN32"; # Bank 13, Vcco=2.5V or 3.3V user selectable by J20 |
---|
306 | NET IIC_SCL_MAIN LOC="F9"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
307 | NET IIC_SCL_SFP LOC="R26"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
308 | NET IIC_SCL_VIDEO LOC="U27"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
309 | NET IIC_SDA_MAIN LOC="F8"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
310 | NET IIC_SDA_SFP LOC="U28"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
311 | NET IIC_SDA_VIDEO LOC="T29"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
312 | NET KEYBOARD_CLK LOC="T26"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
313 | NET KEYBOARD_DATA LOC="T25"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
314 | NET LCD_FPGA_DB4 LOC="T9"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
315 | NET LCD_FPGA_DB5 LOC="G7"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
316 | NET LCD_FPGA_DB6 LOC="G6"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
317 | NET LCD_FPGA_DB7 LOC="T11"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
318 | NET LCD_FPGA_E LOC="AC9"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
319 | NET LCD_FPGA_RS LOC="J17"; # Bank 3, Vcco=2.5V, No DCI |
---|
320 | NET LCD_FPGA_RW LOC="AC10"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
321 | NET LOOPBK_114_N LOC="AG1"; # Bank 118, MGTRXN1_118, GTP_DUAL_X0Y1 |
---|
322 | NET LOOPBK_114_N LOC="AH2"; # Bank 118, MGTTXN1_118, GTP_DUAL_X0Y1 |
---|
323 | NET LOOPBK_114_P LOC="AH1"; # Bank 118, MGTRXP1_118, GTP_DUAL_X0Y1 |
---|
324 | NET LOOPBK_114_P LOC="AJ2"; # Bank 118, MGTTXP1_118, GTP_DUAL_X0Y1 |
---|
325 | NET LOOPBK_116_N LOC="R1"; # Bank 112, MGTRXN1_112, GTP_DUAL_X0Y3 |
---|
326 | NET LOOPBK_116_N LOC="T2"; # Bank 112, MGTTXN1_112, GTP_DUAL_X0Y3 |
---|
327 | NET LOOPBK_116_P LOC="T1"; # Bank 112, MGTRXP1_112, GTP_DUAL_X0Y3 |
---|
328 | NET LOOPBK_116_P LOC="U2"; # Bank 112, MGTTXP1_112, GTP_DUAL_X0Y3 |
---|
329 | NET MOUSE_CLK LOC="R27"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
330 | NET MOUSE_DATA LOC="U26"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
331 | NET PC4_HALT_B LOC="W9"; # Bank 18, Vcco=3.3V, No DCI |
---|
332 | NET PCIE_CLK_QO_N LOC="AF3"; # Bank 118, MGTREFCLKN_118, GTP_DUAL_X0Y1 |
---|
333 | NET PCIE_CLK_QO_P LOC="AF4"; # Bank 118, MGTREFCLKP_118, GTP_DUAL_X0Y1 |
---|
334 | NET PCIE_PRSNT_B_FPGA LOC="AF24"; # Bank 21, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
335 | NET PCIE_RX_N LOC="AF1"; # Bank 118, MGTRXN0_118, GTP_DUAL_X0Y1 |
---|
336 | NET PCIE_RX_P LOC="AE1"; # Bank 118, MGTRXP0_118, GTP_DUAL_X0Y1 |
---|
337 | NET PCIE_TX_N LOC="AE2"; # Bank 118, MGTTXN0_118, GTP_DUAL_X0Y1 |
---|
338 | NET PCIE_TX_P LOC="AD2"; # Bank 118, MGTTXP0_118, GTP_DUAL_X0Y1 |
---|
339 | NET PHY_COL LOC="B32"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 |
---|
340 | NET PHY_CRS LOC="E34"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 |
---|
341 | NET PHY_INT LOC="H20"; # Bank 3, Vcco=2.5V, No DCI |
---|
342 | NET PHY_MDC LOC="H19"; # Bank 3, Vcco=2.5V, No DCI |
---|
343 | NET PHY_MDIO LOC="H13"; # Bank 3, Vcco=2.5V, No DCI |
---|
344 | NET PHY_RESET LOC="J14"; # Bank 3, Vcco=2.5V, No DCI |
---|
345 | NET PHY_RXCLK LOC="H17"; # Bank 3, Vcco=2.5V, No DCI |
---|
346 | NET PHY_RXCTL_RXDV LOC="E32"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 |
---|
347 | NET PHY_RXD0 LOC="A33"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 |
---|
348 | NET PHY_RXD1 LOC="B33"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 |
---|
349 | NET PHY_RXD2 LOC="C33"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 |
---|
350 | NET PHY_RXD3 LOC="C32"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 |
---|
351 | NET PHY_RXD4 LOC="D32"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 |
---|
352 | NET PHY_RXD5 LOC="C34"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 |
---|
353 | NET PHY_RXD6 LOC="D34"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 |
---|
354 | NET PHY_RXD7 LOC="F33"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 |
---|
355 | NET PHY_RXER LOC="E33"; # Bank 11, Vcco=2.5V or 3.3V user selectable by J20 |
---|
356 | NET PHY_TXC_GTXCLK LOC="J16"; # Bank 3, Vcco=2.5V, No DCI |
---|
357 | NET PHY_TXCLK LOC="K17"; # Bank 3, Vcco=2.5V, No DCI |
---|
358 | NET PHY_TXCTL_TXEN LOC="AJ10"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
359 | NET PHY_TXD0 LOC="AF11"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
360 | NET PHY_TXD1 LOC="AE11"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
361 | NET PHY_TXD2 LOC="AH9"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
362 | NET PHY_TXD3 LOC="AH10"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
363 | NET PHY_TXD4 LOC="AG8"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
364 | NET PHY_TXD5 LOC="AH8"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
365 | NET PHY_TXD6 LOC="AG10"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
366 | NET PHY_TXD7 LOC="AG11"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
367 | NET PHY_TXER LOC="AJ9"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
368 | NET PIEZO_SPEAKER LOC="G30"; # Bank 15, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
369 | NET RESERVED1 LOC="AB23"; # Bank 0, Vcco=3.3V |
---|
370 | NET RESERVED2 LOC="AC23"; # Bank 0, Vcco=3.3V |
---|
371 | NET RREF LOC="V4"; # Bank 112, MGTRREF_112, GTP_DUAL_X0Y3 |
---|
372 | NET SATA1_RX_N LOC="Y1"; # Bank 114, MGTRXN0_114, GTP_DUAL_X0Y2 |
---|
373 | NET SATA1_RX_P LOC="W1"; # Bank 114, MGTRXP0_114, GTP_DUAL_X0Y2 |
---|
374 | NET SATA1_TX_N LOC="W2"; # Bank 114, MGTTXN0_114, GTP_DUAL_X0Y2 |
---|
375 | NET SATA1_TX_P LOC="V2"; # Bank 114, MGTTXP0_114, GTP_DUAL_X0Y2 |
---|
376 | NET SATA2_RX_N LOC="AA1"; # Bank 114, MGTRXN1_114, GTP_DUAL_X0Y2 |
---|
377 | NET SATA2_RX_P LOC="AB1"; # Bank 114, MGTRXP1_114, GTP_DUAL_X0Y2 |
---|
378 | NET SATA2_TX_N LOC="AB2"; # Bank 114, MGTTXN1_114, GTP_DUAL_X0Y2 |
---|
379 | NET SATA2_TX_P LOC="AC2"; # Bank 114, MGTTXP1_114, GTP_DUAL_X0Y2 |
---|
380 | NET SATACLK_QO_N LOC="Y3"; # Bank 114, MGTREFCLKN_114, GTP_DUAL_X0Y2 |
---|
381 | NET SATACLK_QO_P LOC="Y4"; # Bank 114, MGTREFCLKP_114, GTP_DUAL_X0Y2 |
---|
382 | NET SFP_RX_N LOC="H1"; # Bank 116, MGTRXN0_116, GTP_DUAL_X0Y4 |
---|
383 | NET SFP_RX_P LOC="G1"; # Bank 116, MGTRXP0_116, GTP_DUAL_X0Y4 |
---|
384 | NET SFP_TX_DISABLE_FPGA LOC="K24"; # Bank 19, Vcco=1.8V, DCI using 49.9 ohm resistors |
---|
385 | NET SFP_TX_N LOC="G2"; # Bank 116, MGTTXN0_116, GTP_DUAL_X0Y4 |
---|
386 | NET SFP_TX_P LOC="F2"; # Bank 116, MGTTXP0_116, GTP_DUAL_X0Y4 |
---|
387 | NET SGMII_RX_N LOC="P1"; # Bank 112, MGTRXN0_112, GTP_DUAL_X0Y3 |
---|
388 | NET SGMII_RX_P LOC="N1"; # Bank 112, MGTRXP0_112, GTP_DUAL_X0Y3 |
---|
389 | NET SGMII_TX_N LOC="N2"; # Bank 112, MGTTXN0_112, GTP_DUAL_X0Y3 |
---|
390 | NET SGMII_TX_P LOC="M2"; # Bank 112, MGTTXP0_112, GTP_DUAL_X0Y3 |
---|
391 | NET SGMIICLK_QO_N LOC="P3"; # Bank 112, MGTREFCLKN_112, GTP_DUAL_X0Y3 |
---|
392 | NET SGMIICLK_QO_P LOC="P4"; # Bank 112, MGTREFCLKP_112, GTP_DUAL_X0Y3 |
---|
393 | NET SMA_DIFF_CLK_IN_N LOC="H15"; # Bank 3, Vcco=2.5V, No DCI |
---|
394 | NET SMA_DIFF_CLK_IN_P LOC="H14"; # Bank 3, Vcco=2.5V, No DCI |
---|
395 | NET SMA_RX_N LOC="J1"; # Bank 116, MGTRXN1_116, GTP_DUAL_X0Y4 |
---|
396 | NET SMA_RX_P LOC="K1"; # Bank 116, MGTRXP1_116, GTP_DUAL_X0Y4 |
---|
397 | NET SMA_TX_N LOC="K2"; # Bank 116, MGTTXN1_116, GTP_DUAL_X0Y4 |
---|
398 | NET SMA_TX_P LOC="L2"; # Bank 116, MGTTXP1_116, GTP_DUAL_X0Y4 |
---|
399 | NET SPI_CE_B LOC="V9"; # Bank 18, Vcco=3.3V, No DCI |
---|
400 | NET SRAM_ADV_LD_B LOC="H8"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
401 | NET SRAM_BW0 LOC="D10"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
402 | NET SRAM_BW1 LOC="D11"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
403 | NET SRAM_BW2 LOC="J11"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
404 | NET SRAM_BW3 LOC="K11"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
405 | NET SRAM_CLK LOC="AG21"; # Bank 4, Vcco=3.3V, No DCI |
---|
406 | NET SRAM_CLK LOC="G8"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
407 | NET SRAM_CS_B LOC="J10"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
408 | NET SRAM_D16 LOC="N10"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
409 | NET SRAM_D17 LOC="E13"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
410 | NET SRAM_D18 LOC="E12"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
411 | NET SRAM_D19 LOC="L9"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
412 | NET SRAM_D20 LOC="M10"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
413 | NET SRAM_D21 LOC="E11"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
414 | NET SRAM_D22 LOC="F11"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
415 | NET SRAM_D23 LOC="L8"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
416 | NET SRAM_D24 LOC="M8"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
417 | NET SRAM_D25 LOC="G12"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
418 | NET SRAM_D26 LOC="G11"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
419 | NET SRAM_D27 LOC="C13"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
420 | NET SRAM_D28 LOC="B13"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
421 | NET SRAM_D29 LOC="K9"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
422 | NET SRAM_D30 LOC="K8"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
423 | NET SRAM_D31 LOC="J9"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
424 | NET SRAM_DQP0 LOC="D12"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
425 | NET SRAM_DQP1 LOC="C12"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
426 | NET SRAM_DQP2 LOC="H10"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
427 | NET SRAM_DQP3 LOC="H9"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
428 | NET SRAM_FLASH_A0 LOC="K12"; # Bank 1, Vcco=3.3V |
---|
429 | NET SRAM_FLASH_A1 LOC="K13"; # Bank 1, Vcco=3.3V |
---|
430 | NET SRAM_FLASH_A2 LOC="H23"; # Bank 1, Vcco=3.3V |
---|
431 | NET SRAM_FLASH_A3 LOC="G23"; # Bank 1, Vcco=3.3V |
---|
432 | NET SRAM_FLASH_A4 LOC="H12"; # Bank 1, Vcco=3.3V |
---|
433 | NET SRAM_FLASH_A5 LOC="J12"; # Bank 1, Vcco=3.3V |
---|
434 | NET SRAM_FLASH_A6 LOC="K22"; # Bank 1, Vcco=3.3V |
---|
435 | NET SRAM_FLASH_A7 LOC="K23"; # Bank 1, Vcco=3.3V |
---|
436 | NET SRAM_FLASH_A8 LOC="K14"; # Bank 1, Vcco=3.3V |
---|
437 | NET SRAM_FLASH_A9 LOC="L14"; # Bank 1, Vcco=3.3V |
---|
438 | NET SRAM_FLASH_A10 LOC="H22"; # Bank 1, Vcco=3.3V |
---|
439 | NET SRAM_FLASH_A11 LOC="G22"; # Bank 1, Vcco=3.3V |
---|
440 | NET SRAM_FLASH_A12 LOC="J15"; # Bank 1, Vcco=3.3V |
---|
441 | NET SRAM_FLASH_A13 LOC="K16"; # Bank 1, Vcco=3.3V |
---|
442 | NET SRAM_FLASH_A14 LOC="K21"; # Bank 1, Vcco=3.3V |
---|
443 | NET SRAM_FLASH_A15 LOC="J22"; # Bank 1, Vcco=3.3V |
---|
444 | NET SRAM_FLASH_A16 LOC="L16"; # Bank 1, Vcco=3.3V |
---|
445 | NET SRAM_FLASH_A17 LOC="L15"; # Bank 1, Vcco=3.3V |
---|
446 | NET SRAM_FLASH_A18 LOC="L20"; # Bank 1, Vcco=3.3V |
---|
447 | NET SRAM_FLASH_A19 LOC="L21"; # Bank 1, Vcco=3.3V |
---|
448 | NET SRAM_FLASH_A20 LOC="AE23"; # Bank 2, Vcco=3.3V |
---|
449 | NET SRAM_FLASH_A21 LOC="AE22"; # Bank 2, Vcco=3.3V |
---|
450 | NET SRAM_FLASH_D0 LOC="AD19"; # Bank 2, Vcco=3.3V |
---|
451 | NET SRAM_FLASH_D1 LOC="AE19"; # Bank 2, Vcco=3.3V |
---|
452 | NET SRAM_FLASH_D2 LOC="AE17"; # Bank 2, Vcco=3.3V |
---|
453 | NET SRAM_FLASH_D3 LOC="AF16"; # Bank 2, Vcco=3.3V |
---|
454 | NET SRAM_FLASH_D4 LOC="AD20"; # Bank 2, Vcco=3.3V |
---|
455 | NET SRAM_FLASH_D5 LOC="AE21"; # Bank 2, Vcco=3.3V |
---|
456 | NET SRAM_FLASH_D6 LOC="AE16"; # Bank 2, Vcco=3.3V |
---|
457 | NET SRAM_FLASH_D7 LOC="AF15"; # Bank 2, Vcco=3.3V |
---|
458 | NET SRAM_FLASH_D8 LOC="AH13"; # Bank 4, Vcco=3.3V, No DCI |
---|
459 | NET SRAM_FLASH_D9 LOC="AH14"; # Bank 4, Vcco=3.3V, No DCI |
---|
460 | NET SRAM_FLASH_D10 LOC="AH19"; # Bank 4, Vcco=3.3V, No DCI |
---|
461 | NET SRAM_FLASH_D11 LOC="AH20"; # Bank 4, Vcco=3.3V, No DCI |
---|
462 | NET SRAM_FLASH_D12 LOC="AG13"; # Bank 4, Vcco=3.3V, No DCI |
---|
463 | NET SRAM_FLASH_D13 LOC="AH12"; # Bank 4, Vcco=3.3V, No DCI |
---|
464 | NET SRAM_FLASH_D14 LOC="AH22"; # Bank 4, Vcco=3.3V, No DCI |
---|
465 | NET SRAM_FLASH_D15 LOC="AG22"; # Bank 4, Vcco=3.3V, No DCI |
---|
466 | NET SRAM_FLASH_WE_B LOC="AF20"; # Bank 2, Vcco=3.3V |
---|
467 | NET SRAM_MODE LOC="A13"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
468 | NET SRAM_OE_B LOC="B12"; # Bank 20, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
469 | NET SYSACE_MPA00 LOC="G5"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
470 | NET SYSACE_MPA01_USB_A0 LOC="N7"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
471 | NET SYSACE_MPA02_USB_A1 LOC="N5"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
472 | NET SYSACE_MPA03 LOC="P5"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
473 | NET SYSACE_MPA04 LOC="R6"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
474 | NET SYSACE_MPA05 LOC="M6"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
475 | NET SYSACE_MPA06 LOC="L6"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
476 | NET SYSACE_MPBRDY LOC="H5"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
477 | NET SYSACE_MPCE LOC="M5"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
478 | NET SYSACE_MPIRQ LOC="M7"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
479 | NET SYSACE_MPOE_USB_RD_B LOC="N8"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
480 | NET SYSACE_MPWE_USB_WR_B LOC="R9"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
481 | NET SYSACE_USB_D0 LOC="P9"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
482 | NET SYSACE_USB_D1 LOC="T8"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
483 | NET SYSACE_USB_D2 LOC="J7"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
484 | NET SYSACE_USB_D3 LOC="H7"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
485 | NET SYSACE_USB_D4 LOC="R7"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
486 | NET SYSACE_USB_D5 LOC="U7"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
487 | NET SYSACE_USB_D6 LOC="P7"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
488 | NET SYSACE_USB_D7 LOC="P6"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
489 | NET SYSACE_USB_D8 LOC="R8"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
490 | NET SYSACE_USB_D9 LOC="L5"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
491 | NET SYSACE_USB_D10 LOC="L4"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
492 | NET SYSACE_USB_D11 LOC="K6"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
493 | NET SYSACE_USB_D12 LOC="J5"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
494 | NET SYSACE_USB_D13 LOC="T6"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
495 | NET SYSACE_USB_D14 LOC="K7"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
496 | NET SYSACE_USB_D15 LOC="J6"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
497 | NET TRC_CLK LOC="AD9"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
498 | NET TRC_TS1E LOC="AK9"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
499 | NET TRC_TS1O LOC="AF10"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
500 | NET TRC_TS2E LOC="AK8"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
501 | NET TRC_TS2O LOC="AF9"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
502 | NET TRC_TS3 LOC="AJ11"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
503 | NET TRC_TS4 LOC="AK11"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
504 | NET TRC_TS5 LOC="AD11"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
505 | NET TRC_TS6 LOC="AD10"; # Bank 22, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
506 | NET USB_CS_B LOC="P10"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
507 | NET USB_INT LOC="F5"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
508 | NET USB_RESET_B LOC="R11"; # Bank 12, Vcco=3.3V, DCI using 49.9 ohm resistors |
---|
509 | NET USER_CLK LOC="AH15"; # Bank 4, Vcco=3.3V, No DCI |
---|
510 | NET VGA_IN_BLUE0 LOC="AC4"; # Bank 18, Vcco=3.3V, No DCI |
---|
511 | NET VGA_IN_BLUE1 LOC="AC5"; # Bank 18, Vcco=3.3V, No DCI |
---|
512 | NET VGA_IN_BLUE2 LOC="AB6"; # Bank 18, Vcco=3.3V, No DCI |
---|
513 | NET VGA_IN_BLUE3 LOC="AB7"; # Bank 18, Vcco=3.3V, No DCI |
---|
514 | NET VGA_IN_BLUE4 LOC="AA5"; # Bank 18, Vcco=3.3V, No DCI |
---|
515 | NET VGA_IN_BLUE5 LOC="AB5"; # Bank 18, Vcco=3.3V, No DCI |
---|
516 | NET VGA_IN_BLUE6 LOC="AC7"; # Bank 18, Vcco=3.3V, No DCI |
---|
517 | NET VGA_IN_BLUE7 LOC="AD7"; # Bank 18, Vcco=3.3V, No DCI |
---|
518 | NET VGA_IN_CLAMP LOC="AH7"; # Bank 18, Vcco=3.3V, No DCI |
---|
519 | NET VGA_IN_COAST LOC="AG7"; # Bank 18, Vcco=3.3V, No DCI |
---|
520 | NET VGA_IN_DATA_CLK LOC="AH18"; # Bank 4, Vcco=3.3V, No DCI |
---|
521 | NET VGA_IN_GREEN0 LOC="Y8"; # Bank 18, Vcco=3.3V, No DCI |
---|
522 | NET VGA_IN_GREEN1 LOC="Y9"; # Bank 18, Vcco=3.3V, No DCI |
---|
523 | NET VGA_IN_GREEN2 LOC="AD4"; # Bank 18, Vcco=3.3V, No DCI |
---|
524 | NET VGA_IN_GREEN3 LOC="AD5"; # Bank 18, Vcco=3.3V, No DCI |
---|
525 | NET VGA_IN_GREEN4 LOC="AA6"; # Bank 18, Vcco=3.3V, No DCI |
---|
526 | NET VGA_IN_GREEN5 LOC="Y7"; # Bank 18, Vcco=3.3V, No DCI |
---|
527 | NET VGA_IN_GREEN6 LOC="AD6"; # Bank 18, Vcco=3.3V, No DCI |
---|
528 | NET VGA_IN_GREEN7 LOC="AE6"; # Bank 18, Vcco=3.3V, No DCI |
---|
529 | NET VGA_IN_HSOUT LOC="AE7"; # Bank 18, Vcco=3.3V, No DCI |
---|
530 | NET VGA_IN_ODD_EVEN_B LOC="W6"; # Bank 18, Vcco=3.3V, No DCI |
---|
531 | NET VGA_IN_RED0 LOC="AG5"; # Bank 18, Vcco=3.3V, No DCI |
---|
532 | NET VGA_IN_RED1 LOC="AF5"; # Bank 18, Vcco=3.3V, No DCI |
---|
533 | NET VGA_IN_RED2 LOC="W7"; # Bank 18, Vcco=3.3V, No DCI |
---|
534 | NET VGA_IN_RED3 LOC="V7"; # Bank 18, Vcco=3.3V, No DCI |
---|
535 | NET VGA_IN_RED4 LOC="AH5"; # Bank 18, Vcco=3.3V, No DCI |
---|
536 | NET VGA_IN_RED5 LOC="AG6"; # Bank 18, Vcco=3.3V, No DCI |
---|
537 | NET VGA_IN_RED6 LOC="Y11"; # Bank 18, Vcco=3.3V, No DCI |
---|
538 | NET VGA_IN_RED7 LOC="W11"; # Bank 18, Vcco=3.3V, No DCI |
---|
539 | NET VGA_IN_SOGOUT LOC="AF6"; # Bank 18, Vcco=3.3V, No DCI |
---|
540 | NET VGA_IN_VSOUT LOC="Y6"; # Bank 18, Vcco=3.3V, No DCI |
---|